Connections and Wiring
Connections
Gateway Wiring:
Pin | Name | Description | Recommended wiring |
---|---|---|---|
1 |
POWER |
Positive power output to 10Scene Wall plates |
CAT5e Orange pair (twisted together) |
2 |
TRIG IN |
Trigger input 5V logic or close contact to POWER - |
Not used for 10Scene |
3 |
10Scene H |
10Scene signal High |
CAT5e Blue/white wire |
4 |
10Scene L |
10Scene signal Low |
CAT5e Blue wire |
5 |
POWER - |
Negative power output to 10Scene Wall plates |
CAT5e Brown pair (twisted together) |
image::gateway_wiring.png[Gateway wiring
When facing the 10Scene Ports on the Gateway, Pin 1 is found on the left (towards the Power/Comms LEDs).
A Contact close switch is wired between Pins 2 & 5.
10Scene Wall Plate Wiring
10Scene wall plates feature a 7 pin push lock cable connector which is wired using the below table. 10Scene Wall mounts should be wired before connecting to QuickQ Rack/Gateway Interface.
Pin | Name | Description | Recommended wiring |
---|---|---|---|
1 |
POWER |
Positive power in/out |
CAT5e Orange pair IN (twisted together) |
2 |
POWER |
Positive power in/out |
CAT5e Orange pair OUT (twisted together) |
3 |
10Scene H |
10Scene signal High in/out |
CAT5e Blue/white wire IN/OUT |
4 |
10Scene L |
10Scene signal Low in/out |
CAT5e Blue wire IN/OUT |
5 |
10Scene 0V |
10Scene 0V (NOT USED) |
NOT USED |
6 |
POWER - |
Negative power in/out |
CAT5e Brown pair IN (twisted together) |
7 |
POWER- |
Negative power in/out |
CAT5e Brown pair OUT (twisted together) |
When looking at the rear of the 10Scene Pin 7 is at the top and Pin 1 at the bottom.
If daisy-chaining, twist 10Scene High IN and the OUT wires together and connect to Pin 3, and twist 10Scene Low IN and the OUT wires together and connect to Pin 4. When 10Scene Wall Mounts are first connected to a 10Scene Gateway the front panel LEDs of each 10Scene will flash briefly indicating the unit is powered and connected.
Connecting to a MagicQ/QuickQ Console
Gateway interfaces are ChamNet enabled devices that are managed through the ChamNet, where the devices IP address, subnet mask & ID can be configured, along with new firmware uploaded to them.
On MagicQ systems, the ChamNet window is found in the View DMX I/O, Net Manager window. For QuickQ consoles/racks, Gateways are configured in the 10Scene, Gateways window.
10Scene gateways ship from the factory with a default 10.x.x.x IP address, with a /8 subnet (255.0.0.0). For system programming refer to the MagicQ or QuickQ software manuals found on the ChamSys website (www.chamsys.co.uk).