Contact Triggers

The GN5 and GN10 support a Contact Trigger input, this is wired to 2 pins on the 10Scene Port on the devices.

Trigger Mode

The trigger mode determines whether the trigger input is activated on close or open of the circuit, and whether it persists when the circuit is reopened / closed.

The options are:

Table 1. Trigger Modes
Trigger Option Function

Active while open

The trigger activates when the circuit is opened, and released when the circuit is closed

Active while closed

The trigger activates when the circuit is closed, and released when the circuit is opened

Persistent on open

The trigger activates when the circuit is opened and remains active

Persistent on close

The trigger activates when the circuit is closed and remains active

Trigger Scene

The GN2, GN10 and 10Scene Store support a trigger input on the 10Scene port.

The trigger input can be set to activate one of the ten Scenes when the trigger occurs.