Quick Setup
The Quick Setup menu contains a choice of 6 common preset Node configurations. These configurations are:
Menu Option | Menu Action |
---|---|
Art-Net 0..1 |
Sets Node into Art-Net mode, sets Ports to sequential universes with Port 1 set to Art-Net Universe 0, Port 2 to Art-Net Universe 1 and so on. |
Art-Net 1..2 |
Sets Node into Art-Net mode, sets Ports to sequential universes with Port 1 set to Art-Net Universe 1, Port 2 to Art-Net Universe 2 and so on. |
Art-Net 0..0 |
Sets Node into Art-Net mode, sets all Ports to the same Art-Net Universe - Art-Net 0. All ports will output Art-Net Universe 0. |
sACN 1..2 |
Sets Node into sACN mode, sets Ports to sequential universes with Port 1 set to sACN Universe 1, Port 2 to sACN Universe 2 and so on. |
sACN 1..1 |
Sets Node into sACN mode, sets all Ports to the same sACN Universe - sACN 1. All ports will output sACN Universe 1. |
Splitter |
Option available on GN5 and GN10, in this mode device acts as a DMX Splitter. Sets port 1 to DMX Input, Ports 2 onwards output data received from Port 1. Art-Net / sACN input is ignored in this mode. |
When using the GN5 / GN10 in Splitter mode RDM messages are not supported. RDM Messages are ignored / not passed through by the GN5 / GN10 when used in Splitter mode. |