Quick Setup

The Quick Setup menu contains a choice of 6 common preset Node configurations. These configurations are:

Table 1. QuickQ Setup Menu Options
Menu Option Menu Action

Art-Net 0..1

Sets Node into Art-Net mode, sets Ports to sequential universes with Port 1 set to Art-Net Universe 0, Port 2 to Art-Net Universe 1 and so on.

Art-Net 1..2

Sets Node into Art-Net mode, sets Ports to sequential universes with Port 1 set to Art-Net Universe 1, Port 2 to Art-Net Universe 2 and so on.

Art-Net 0..0

Sets Node into Art-Net mode, sets all Ports to the same Art-Net Universe - Art-Net 0. All ports will output Art-Net Universe 0.

sACN 1..2

Sets Node into sACN mode, sets Ports to sequential universes with Port 1 set to sACN Universe 1, Port 2 to sACN Universe 2 and so on.

sACN 1..1

Sets Node into sACN mode, sets all Ports to the same sACN Universe - sACN 1. All ports will output sACN Universe 1.

Splitter

Option available on GN5 and GN10, in this mode device acts as a DMX Splitter. Sets port 1 to DMX Input, Ports 2 onwards output data received from Port 1. Art-Net / sACN input is ignored in this mode.