GeNetix Nodes Quick Start

Overview

All GeNetix Nodes ship with a default IP address in the 10.X.Y.Z range, using a 255.0.0.0 subnet mask.

IP Address Configuration

*GN2, GN5, GN10, GN10P, GN10R Change IP via the device display/menu, Web Server, or ChamNet (Net Manager) using MagicQ/QuickQ consoles.

*GW2O, GW2I, GN4IP Change IP via Web Server or ChamNet only.

Default Output Settings

*Protocol: Art-Net (DMX Output mode)

*First DMX Output: Art-Net Universe 0

*Supported Protocols: Art-Net and sACN

Simple Setup: Direct Connection to a Lighting Console

In this setup, the GeNetix Node connects directly to the lighting console using a Cat5/Cat6 cable.

ChamSys console → GeNetix Node
The steps below assume Art-Net is used as the Ethernet–DMX protocol.

Steps

*Connect a network cable between the lighting console and the GeNetix Node.

*Power On

GW2O/GW2I: Requires a PoE injector.

GN2: Powered by USB or PoE.

GN4, GN5, GN10, GN10P, GN10R: Powered by PoE or mains.

*Set Console IP

Example: 10.0.0.10 with subnet 255.0.0.0.

Refer to your console’s manual for instructions.

*Enable Art-Net Output on Console

Example (MagicQ):

Setup > View DMX I/O

Enable Universe 1

Set Out Type to Art-Net

Set first Universe Out Uni to Universe 0.

*Configure Node Ports

GN2, GN5, GN10, GN10P, GN10R: Use Quick Setup menu, select Art-Net 0..1 (Port 1 → Universe 0, Port 2 → Universe 1, etc.).

GW2O, GW2I, GN4IP: Recommended to configure initially via MagicQ PC (custom IP & port settings). Use Net Manager:

Setup > View DMX I/O > Net Manager.

*Verify DMX Output

Blue LED next to DMX port = DMX is being output from that port.

Multi-Node Setup: Using a Network Switch

In this setup, multiple GeNetix Nodes connect via a network switch (e.g., GeNetix GS8) to a lighting console — ideal for distributed stage setups.

ChamSys console → GeNetix Nodes via Network Switch

Steps

*Connect the lighting console to the network switch.

*Connect each GeNetix Node to the network switch.

*Set Console IP — e.g., 10.0.0.10 / 255.0.0.0.

*Enable Art-Net Output on Console — as per Section 1, Step 4.

*Configure First Node Ports — as per Section 1, Step 5.

*Verify DMX Output — Blue LED indicates active DMX output.

*Repeat Steps 4–7 for each additional node, enabling more universes on the console as needed.

Quick Reference

GeNetix Node Default IP: 10.X.Y.Z / 255.0.0.0

Default Protocol: Art-Net

Node DMX Port LED Status: Blue = DMX Output Active